Journal of the Korean Ophthalmological Society ; : 345-351, 2022.
Article in Korean | WPRIM | ID: wpr-926319

ABSTRACT

Purpose@#To confirm that the phaco chop method using an illuminated chopper (iChopper; Oculight, Seongnam, Korea) can reduce cataract surgery complications, and that even beginners can safely and effectively perform phaco chop. @*Methods@#We retrospectively analyzed the medical records of the first 30 phaco chop cases using illuminated chopper of four cataract surgeons. Four ophthalmologists had a variety of empirical backgrounds, from those who have experienced more than 10,000 cataract surgery, to beginners who have experienced 20 cataract surgery. @*Results@#Of the total 120 eyes, two eyes (1.67%) had posterior capsule rupture. The chopping method was changed from phaco chop to stop and chop in three eyes (2.5%) including one eye with brown cataract with pseudoexofoliation syndrome and two eyes with nuclear opacity grade ≥5. @*Conclusions@#The rates of posterior capsule rupture of phaco chop using an illuminated chopper were very low in four surgeons with various experiences and who became proficient shortly in phaco chop.